Aucotec AG has released ELCAD/AUCOPLAN Version 2019. This release has incorporated a total of more than 60 enhancements that have been derived from your requirements and requests.
New Features of ELCAD/AUCOPLAN Version 2019
ELCAD/AUCOPLAN Version 2019 continues the ongoing evolution of the past years.
Already with the setup, we provide you with a multitude of additional language and data environments. Thus, multilingual environments are available for international organizations right from the beginning. From now on, the direct access to the New Features WebHelp provides your users with up-to-date information online.
With the new Product key dialog, there is a further innovation which enables you to manage your licenses in a very flexible manner. With ELCAD/AUCOPLAN 2019, you can now check out server licenses for a limited period of time and, in that period of time, use them on local work stations independent of the license server.
Moreover, the refined checks in the status list Working Status enable you to define efficient project status checks in which you do no longer have to ignore any error messages.
In ELCAD/AUCOPLAN 2019, AUCOTEC has incorporated a total of more than 60 enhancements that have been derived from your requirements and requests.
As in all our extensions, our focus has again been on the compatibility of your data and on an easier handling.
- 151520
On creating standard strips as well as on working in the Terminal Block Designer, users can define whether a terminal is to be displayed in the parts list or not. However, this status information was not transferred into the parts list.
- 162532
On saving drawings as Compact PDF, faulty tooltips were created in the PDF for item designations composed of project texts "\z" and fixed texts. However, the item designations themselves were correct in the PDF.
- 166734
Deleting revisions in the drawings tree was only possible directly on the revision document or on the uppermost folder "Drawings". On all folder levels in-between, deleting revisions was not offered for selection on the shortcut menu.
- 170707
In the ELCAD print dialog, there is the option "Sorting Instead of Grouping". However, the setting of this option was not saved in ELCAD for batch outputs. As a consequence, the option "Grouping" was always sent to the printer for batch outputs.
- 186161
In the "External Documents" tree, it was not possible to delete documents on the uppermost folder "External Documents". On right-clicking, the function "Delete" was offered, but did not function.
- 186555
In various ELCAD drawing editing dialogs, numbers and lines were illegible under Windows 10 as of a certain build.
This issue occurred, among others, in the following dialogs:
- In the terminal editor
- On editing the line type of lines, circles, ellipses and connections
- On selecting translate texts
- 196935
In ELCAD 2018, the ASCII output of drawings has been extended by the option "Translate Translate References". However, this option was not available for the batch action "Output drawings as ASCII file".
- 199311
If Excel files were imported via protocols and it was specified that not all columns were to be read in during that import, numerical columns with decimal places were erroneously interpreted as alphanumeric columns. Subsequently, an error message was issued that the data field types did not match, and the data was not imported.
- 204633
On changing batch definitions in which the batch action "Replace Symbol Texts and Free Texts" was included, ELCAD issued an error message. Moreover, the batch definition dialog was not initialized with the existing values.
- 205264
If a batch to create Compact PDF was called in a process and a path to a not yet existing folder was defined in that batch, an error occurred.
In that case, copying the already created PDF files from the temporary folder was stopped instead of the missing folder being created.
- 211191
Renaming main representations by editing type 5 symbols in the drawing editing mode only worked if the option "Add New Part Numbers to Database after Editing Symbols" was set as working method for the master data. Now it works again, independent from this setting.
- 211710
Reading in DXF/DWG files led to an error message "[3094] 'DXF code number missing'" if there was no ELCAD version 7.10 or older installed on the computer.
- 216059
When terminal diagrams should be generated by means of the variant "Terminal Connection Diagram", an error message was issued if no diagrams existed.
- 217223
If content of main representation symbols was changed from within other main representation symbols by using the function "Edit With Transfer", the status was set to "Manually", even if code numbers were changed which were not relevant for the item designation or the assignment of secondary representations.
Now, main representations keep their status if content is transferred which neither changes the item designation nor the assignment of secondary representations.
- 218795
If the status list "Used Symbols" was regenerated via a process, the two options offered in the "Regenerate Used Symbols" dialog on manual execution were always active. Therefore, no differing configuration could be used via a process.
- 218859
The function "Edit / Rename Designation Block" in ELCAD projects did not work in certain constellations. If "Presigns =.+-/Add Automatically" was set in the project, the function was not executed once the content of the code numbers 1, 2 or 3 was defined in the form sheet with presigns.
For the symbol type 11, the function was not executed if the content of the code numbers 1, 2 or 3 in the symbol differed from the form sheet entries.
- 220718
If drawings of a project were output via "Save as/PDF/Compact PDF", the program was aborted under Windows 10 if the name of the project had the maximum possible length of 32 characters.
- 220723
If multipolar symbols were placed on drawings via Autoconnect and, during the placement, the pen type was changed via the "S" key or the line type was changed via the "L" key, this change did not become effective for all connections. The same behaviour also occurred if the right mouse key was pressed during the placement and the abovementioned settings were made in the "digitalizing parameters" dialog.
About ELCAD. For over three decades ELCAD has been successful in the market as a well-engineered, highly efficient tool for the production of electrical documentation. Right from the beginning, ELCAD was data-compatible version by version and stands for long-term security of investment. The entire operating philosophy is focused on intuition and efficiency. As a result, ELCAD delivers intelligent PDF files in which entire projects are summarized in a navigable way, but also other popular formats such as DWG.
ELCAD is popular in Europe and used worldwide. All current standards for the documentation of electrical engineering systems are supported and, due to its flexibility, the system has also been adapted to many industry and corporate guidelines. Wherever consistent electrical documentation is required, ELCAD is in use today - from mechanical engineering, plant construction and rail vehicles to power plants.
About AUCOPLAN At the beginning of the 1990s, with AUCOPLAN one of the first specialist systems for the documentation of I&C technical systems was introduced. Based on the graphical and electrical capabilities of ELCAD, tables were developed for the definition of plant objects in a structured plant model. The equal balance of graphic and alphanumeric processing had its beginnings here.
AUCOPLAN achieved the greatest accelerating effect by introducing automated generation of I&C loop diagrams based on standardized templates (typicals). After tabular preliminary work, the documents for measuring points and consumers are generated large-scale at the touch of a button. All follow-up documents for detailed planning are created by the integrated ELCAD - you can't get any faster than that.
Because of its innovative approach, AUCOPLAN has become widely used. AUCOPLAN is used everywhere where I&C engineering is to be documented. AUCOPLAN is at home anywhere from chemical plants and the pharmaceutical industry to power plants, - the more measuring points, the better.
About Aucotec AG. Aucotec AG has over 30 years of experience in developing engineering software for the entire life cycle of machines, plants and mobile systems. The solutions range from flow diagrams through control and electrical engineering for large-scale plants to modular harness design in the automotive industry. Aucotec software is in use all over the world. In addition to its headquarters in Hanover, Aucotec operates six further sites in Germany as well as subsidiaries in China, France, the United Kingdom, Italy, Austria, Poland, Sweden and the US. A global network of partners ensures local support throughout the world.
Product: Elcad / Aucoplan
Version: 2019 version 17.14.0 build 6647
Supported Architectures: 32bit / 64bit
Website Home Page :
www.aucotec.com
Language: multilanguage
System Requirements: PC
Supported Operating Systems: Windows 7even SP1 or newer / Server 2016, 2012 R2, 2012, 2008 SP1 R2, 2008 SP2
Size: 690.5 mb
DOWNLOAD LINKS :
Немного информации об материале: 20-04-2019, 17:29 наш лучший журналист - apple2000 написал статью - "Elcad / Aucoplan 2019 version 17.14" и сразу же добавил её к нам на сайт! Хотелось бы добавить, что наш журналист подобрал лучшее оформление и качественное содержание данной новости. Так же советуем вам посетить категорию Софт, чтобы найти другие отличные материалы, как и этот!